BGMZ LLC offers automation and instrumentation for comprehensive protection of screw pumping units from dry running, excess pressure from the norm at the pump outlet and discharge at the inlet.
The temperature sensor controls the heating of the gerotor steam — if the limit is exceeded, the pump automatically turns off.
Pressure control at the pump outlet — prevention of overloads and damage to the pipeline
Vacuum control at suction — prevention of cavitation and supply failure
Automation with measuring controls, buttons and warning lights
BGMZ LLC offers control and measuring devices and automation for complex protection of screw pumping units. The system provides control of three critical parameters: protection against “dry running”, overpressure at the outlet and discharge at the inlet.
The package includes:
Protection against “dry running”
“Dry running” is an emergency operation mode of the pump, in which there is no pumped medium. The liquid performs the function of lubrication and cooling of the gerotor pair, so its absence leads to overheating and deformation of the working elements.
The protection system turns off the pump when the critical temperature is reached. Principle of operation: the sensor (thermocouple) controls the heating of the gerotor pair, the thermostat compares the readings with the set limit, and the control cabinet stops the unit.
Additional equipment
At the request of the customer, the pumps are equipped with frequency converters for smooth flow control. Advantages of using:
To ensure the operation of double mechanical seals, non-removable tanks are offered, equipped with a visual liquid monitoring level, a pressure gauge and a temperature sensor. It can be equipped with additional monitoring devices according to the customer’s technical specifications.
Comprehensive protection for three critical parameters: dry running, overpressure, discharge at the inlet
The control cabinet is complete with automation, measuring regulators, buttons and warning lights
Temperature, pressure and discharge sensors in general industrial or explosion-proof design (Ex)
Protection against "dry running" by controlling the heating of the gerotor pair with a thermocouple — shutdown when the critical temperature is reached
Preventing deformation of the rotor and stator due to overheating in the absence of the pumped medium
Overpressure protection at the outlet — prevention of pump overload and pipeline rupture
Discharge protection at the inlet — prevention of cavitation and supply failure
Frequency converters optional — smooth start, motor protection, energy saving
Non—removable tanks for double mechanical seals - visual level control, pressure gauge, temperature sensor
The possibility of completing additional monitoring devices according to the customer's technical specifications
Work in all conditions due to the explosion-proof design of sensors and automation
Submit a request and our engineers will help you choose the right pump for your needs